The Bingham Canyon Mine 2002 is a Welded Wire Wall that was constructed in 2002 by Ames Construction Inc., and was designed by Geotechnical Design Services Inc.
Wall Details:
- West Wing Wall: 6,144 FSF (supplied)
- 20 year design life
- Design Loading: Crane CT-2000 Transporter; Maximum Load of 8.5 ksf
- 3 angle points
- Maximum Wall height 42’
- Maximum Mat length of 35’
- Truck Dump Wall: 24,208 FSF (supplied)
- Design Loading: CAT 797 Truck
- 5 angle points
- Maximum Wall height 62’
- Maximum Mat length 40’
Wall Type:
Welded Wire Wall
Wire Type:
Non-Galvanzied
Owner Type:
Mining
Wall Height:
Wall Size:
Over 5000 SF